Hinc II
5'...GTPy↓PuAC...3'
3'...CAPu↑PyTG...5'
Source
Haemophilus influenzae Rc
Reagents Supplied
CMX Buffer 5
Unit Definition
One unit is the amount of enzyme required to completely digest 1 µg of lambda DNA in 1 hour in a total reaction volume of 50 µl
Star Activity
No
Incubation Temperature
37°C
Heat Inactivation
65°C for 10 minutes
Assay Unit Substrate
Lambda DNA
Reaction Buffer
CMX Buffer 5:
20 mM Tris-HCl (pH 7.0 at 37°C)
5 mM MgCl2
50 mM KCl
1 mM dithiothreitol
100 µg/ml bovine serum albumin
Activity in Buffers
Buffer 1: 50%
Buffer 2: 50%
Buffer 3: 75%
Buffer 4: >75
Buffer 5: 100%
Storage Buffer
10 mM Tris‑HCl (pH 7.4 at 4°C)
200 mM NaCl
0.1 mM EDTA
1 mM dithiothreitol
500 μg/ml bovine serum albumin
5 μg/ml poly-L-lysine
0.1% Triton X-100™
50% (v/v) glycerol
Assay Conditions
1 mM DTT
100 μg/ml BSA
20 mM Tris‑HCl (pH 7.0 at 37°C)
50 mM KCl
5 mM MgCl2
1 μg lambda DNA
Incubation is at 37°C for 1 hour in a total reaction volume of 50 μl
Storage Conditions
Store at -20°C
Shipped on dry ice
Downloads
Certificate of Analysis PDF -Current Lot
MSDS PDF -Current Lot